elektronik mainzOS-9 V2.4 on EUROCOM-17Installation GuideSoftware ManualRevision 1 A
How to Use this Manual OS-9 V2.4 on EUROCOM-17VIII Software ManualHow to Use this ManualDocument Conventions Font Types:Other conventions:Indicates in
OS-9 V2.4 on EUROCOM-17 1 Getting StartedSoftware Manual 11 Getting StartedThis manual contains informations about the implementation dependentpart
1 Getting Started OS-9 V2.4 on EUROCOM-172 Software ManualIf you want to use a VGA monitor and MF-2 keyboard, set hex switch S2to '0'. Conn
OS-9 V2.4 on EUROCOM-17 2 Installing OS-9 V2.4.5Software Manual 32 Installing OS-9 V2.4.5 This chapter explains the installation of the new OS-9 rel
2 Installing OS-9 V2.4.5 OS-9 V2.4 on EUROCOM-174 Software ManualType 'c' to change boot controller."Controller: TEAC"Press &apos
OS-9 V2.4 on EUROCOM-17 2 Installing OS-9 V2.4.5Software Manual 52.2 Installing OS-9 V2.4.5 on an Empty HarddiskIt is recommended to install the ope
2 Installing OS-9 V2.4.5 OS-9 V2.4 on EUROCOM-176 Software Manual2.3 Updating OS-9 V2.X to V2.4.5 Installing the software on a harddisk already cont
OS-9 V2.4 on EUROCOM-17 2 Installing OS-9 V2.4.5Software Manual 74. Generate a new boot file on the harddisk with os9gen. Examine thesample bootlist
2 Installing OS-9 V2.4.5 OS-9 V2.4 on EUROCOM-178 Software Manual2.4.2 OS-9 Configuration without SSMELTEC supplies two modified syscache040 modules
OS-9 V2.4 on EUROCOM-17 2 Installing OS-9 V2.4.5Software Manual 92.4.4 Notes and RestrictionsThe DDIO bit in module init is set by default. This tell
Revision History OS-9 V2.4 on EUROCOM-17Rev. Changes DateRev. Changes DateDISCLAIMER!The information in this document has been carefully checked and i
2 Installing OS-9 V2.4.5 OS-9 V2.4 on EUROCOM-1710 Software Manual2.5 Floating Point SupportThis release provides soft- and hardware floating point
OS-9 V2.4 on EUROCOM-17 2 Installing OS-9 V2.4.5Software Manual 112.6 Memory Configuration with MemList The memory size is set to 2MB per default wi
2 Installing OS-9 V2.4.5 OS-9 V2.4 on EUROCOM-1712 Software Manual
OS-9 V2.4 on EUROCOM-17 3 Drivers and DescriptorsSoftware Manual 133 Drivers and DescriptorsThis chapter describes the drivers and descriptors for c
3 Drivers and Descriptors OS-9 V2.4 on EUROCOM-1714 Software Manual3.2 RBF DriversThe RBF drivers are structured in a physical and logical part.• sc
OS-9 V2.4 on EUROCOM-17 3 Drivers and DescriptorsSoftware Manual 153.3 RBF DescriptorsThe source of these descriptors is located in the IO/RBF direc
3 Drivers and Descriptors OS-9 V2.4 on EUROCOM-1716 Software Manual3.3.2 Descriptors for TEAC FC-1 ControllerAll descriptors are for SCSI ID 3.• d0.t
OS-9 V2.4 on EUROCOM-17 3 Drivers and DescriptorsSoftware Manual 173.4 SCF Drivers and Descriptors• scrmon Depending on the setup of the RMon, the V
3 Drivers and Descriptors OS-9 V2.4 on EUROCOM-1718 Software ManualTable1: Available SCF Descriptors and Appropriate DriversThe sources of the descr
OS-9 V2.4 on EUROCOM-17 3 Drivers and DescriptorsSoftware Manual 193.5 SBF Drivers and DescriptorsFor each supported streamer there is a driver and
Table of ContentsPageOS-9 V2.4 on EUROCOM-17 Table of ContentsSoftware Manual ITable of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Drivers and Descriptors OS-9 V2.4 on EUROCOM-1720 Software ManualThe following descriptors are available:SCFL floppy descriptors are also available
OS-9 V2.4 on EUROCOM-17 4 Installing new RBF DevicesSoftware Manual 214 Installing new RBF DevicesThe new OS-9 V2.4 release is no longer restricted
4 Installing new RBF Devices OS-9 V2.4 on EUROCOM-1722 Software Manual4.2 Fixed Device ParametersTable3: Used SCSI IDs on EUROCOM-17SCSI-ID LUN D
OS-9 V2.4 on EUROCOM-17 5 Features and EnhancementsSoftware Manual 235 Features and EnhancementsThis chapter describes the changes in the ELTEC depe
5 Features and Enhancements OS-9 V2.4 on EUROCOM-1724 Software Manual
OS-9 V2.4 on EUROCOM-17 6 Additional UtilitiesSoftware Manual 256 Additional Utilities6.1 Dmode UtilityAs an addition to the Microware utilities, E
6 Additional Utilities OS-9 V2.4 on EUROCOM-1726 Software Manuallsnoffs=<n> offset to first logical sectordisconn=on|off enable/disable SCSI
OS-9 V2.4 on EUROCOM-17 6 Additional UtilitiesSoftware Manual 27The following streamer types are supported:mt0.scsi for the Tandberg 3620/40/60 Stre
6 Additional Utilities OS-9 V2.4 on EUROCOM-1728 Software Manual-z[=<filename>] Reads an exclude list. None of the files/subdirectories in this
OS-9 V2.4 on EUROCOM-17 6 Additional UtilitiesSoftware Manual 29-n Asks if existing destination file with same name shallbe overwritten. (default)-u
PageTable of Contents (Continued) OS-9 V2.4 on EUROCOM-17II Software Manual3.3 RBF Descriptors . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Additional Utilities OS-9 V2.4 on EUROCOM-1730 Software Manualb) Make backups on disks using a saveset:$ back /h0/SOURCES -s=/d0/savesource >/h0
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 317 Additional Libraries7.1 The F$System System CallThe F$System system call has been
7 Additional Libraries OS-9 V2.4 on EUROCOM-1732 Software Manual7.2 The Assembler Library LIBELTECThe following section contains the complete descri
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 33Sys$IOS Get mmu-protected I/O segment❏ Input:d0.w = 0 (Sys$IOS function code)d1.l =
7 Additional Libraries OS-9 V2.4 on EUROCOM-1734 Software ManualSys$VMECCtl Enable/disable caching of VMEbus read cycles❏ Input:d0.w = 1 (Sys$VMECCt
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 35Sys$DSCtrl0 Data size control 0 (A32)❏ Input:d0.w = 2 (Sys$DSCtrl0 function code)d1.
7 Additional Libraries OS-9 V2.4 on EUROCOM-1736 Software ManualSys$DSCtrl1 Data size control 1 (A24)❏ Input:d0.w = 3 (Sys$DSCtrl1 function code)d1.
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 37Sys$ASCtrl0 Select VMEbus AM source❏ Input:d0.w = 4 (Sys$ASCtrl0 function code)d1.l
7 Additional Libraries OS-9 V2.4 on EUROCOM-1738 Software ManualSys$BlkDisp Enable/disable hex display❏ Input:d0.w = 6 (Sys$BlkDisp function code)d1
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 39Sys$EnSemIRQH Enable/disable semaphore interrupt at $7C❏ Input:d0.w = 7 (Sys$EnSemIR
List of TablesPageOS-9 V2.4 on EUROCOM-17 List of TablesSoftware Manual IIITable1: Available SCF Descriptors and Appropriate Drivers . . . . . . . . .
7 Additional Libraries OS-9 V2.4 on EUROCOM-1740 Software ManualSys$EnAbort Enable abort switch❏ Input:d0.w = 8 (Sys$EnAbort function code)d1.l = 1:
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 41Sys$SlavAddr Set VMEbus slave base address❏ Input:d0.w = 10 (Sys$SlavAddr function co
7 Additional Libraries OS-9 V2.4 on EUROCOM-1742 Software ManualSys$BlkMove VMEbus block transfer via VIC❏ Input:d0.w = 11 (Sys$BlkMove function cod
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 43Sys$AlignPtr Align pointer to 256 byte boundary❏ Input:d0.w = 12 (Sys$AlignPtr functi
7 Additional Libraries OS-9 V2.4 on EUROCOM-1744 Software ManualSys$SetDisp Set digit of hex display❏ INPUT:d0.w = 13 (Sys$SetDisp function code)d1.l
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 457.3 The C Library CLIBELTECThe following section contains complete description of th
7 Additional Libraries OS-9 V2.4 on EUROCOM-1746 Software Manualvme_cctl() Enable/disable caching of VMEbus READ cycles❏ Synopsis:int vme_cctl (cntrl
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 47ds_cntrl1() Data size control 1 (A24)❏ Synopsis:int ds_cntrl1 (cntrl)int cntrl; /* 1
7 Additional Libraries OS-9 V2.4 on EUROCOM-1748 Software Manualblk_disp() Enable/disable hex display❏ Synopsis:int blk_disp (cntrl)int cntrl; /* 1:
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 49en_abort() Enable abort switch❏ Synopsis:int en_abort(cntrl)int cntrl; /* 1: enables
OS-9 V2.4 on EUROCOM-17IV Software Manual
7 Additional Libraries OS-9 V2.4 on EUROCOM-1750 Software Manualslave_addr() Set VMEbus slave base address❏ Synopsis:int slave_addr (std_addr, ext_ad
OS-9 V2.4 on EUROCOM-17 7 Additional LibrariesSoftware Manual 51align_ptr() Align a given pointer to a 256 byte boundary❏ Synopsis:long *align_ptr (p
7 Additional Libraries OS-9 V2.4 on EUROCOM-1752 Software Manual
OS-9 V2.4 on EUROCOM-17 Appendix A: Control Sequence CodesSoftware Manual 53Appendix A: Control Sequence CodesANSI Standard Terminal EmulationThe s
Appendix A: Control Sequence Codes OS-9 V2.4 on EUROCOM-1754 Software Manual<ESC> represents the ASCII escape character (<ESC>, <Ctr
OS-9 V2.4 on EUROCOM-17 Appendix A: Control Sequence CodesSoftware Manual 55If a syntactical error is found within a sequence, the sc17cons outputf
Appendix A: Control Sequence Codes OS-9 V2.4 on EUROCOM-1756 Software Manual• <ESC> [ <n> M Delete Line (DL)Takes one parameter, <n&
Scope of DeliveryDescription: Order No.:OS-9 V2.4 on EUROCOM-17 Scope of DeliverySoftware Manual VThe last letter of the order numbers refers to the s
OptionsDescription: Order No.:Options / Related Products OS-9 V2.4 on EUROCOM-17VI Software ManualRelated ProductsDescription: Order No.:The last lett
ConventionsIf not otherwise specified, addresses are written in hexadecimal notationand identified by a leading dollar sign ("$").Signal nam
Kommentare zu diesen Handbüchern